{"product_id":"sloan-eaf-275-parts-breakdown-and-troubleshooting-guide","title":"Sloan EAF-275 Parts Breakdown and Troubleshooting Guide","description":"Troubleshooting Q\u0026amp;A\nBelow is a Troubleshooting Q\u0026amp;A Guide for the Solis EAF-275 Electronic Faucet from Sloan. The guide highlights the most commonly occurring problems and how to go about fixing them. As always you can call us for assistance or if you need to replace a part and\/or unit.\n1\nPROBLEM:\nFaucet does not function\nSOLUTION:\nA) Adhesive packaging label is still affixed over sensor eye. Remove adhesive label from sensor eye.\nB) \"Permanent Off\" activated. Press button on faucet throat one time.\n2\nPROBLEM:\nDelivery of water is uncontrollable\nSOLUTION:\nA) Faucet is not working properly. Please contact Equiparts at 800-442-6622 or view replacement EAF-275 complete faucets: #58112, #58114.\n3\nPROBLEM:\nFaucet DOES NOT deliver any water when Sensor is activated\nINDICATOR:\nSolenoid valve produces audible \"CLICK.\"\nSOLUTION:\nA) Water supply stop(s) closed. Open supply stop(s) completely.\nB) Water supply stop strainer(s) clogged. Clean water supply stop strainer(s)\nINDICATOR:\nSolenoid valve DOES NOT produce audible \"CLICK\"\nSOLUTION:\nA) Battery low. Replace battery (#80775).\n4\nPROBLEM:\nFaucet delivers only a slow flow or dribble when sensor is activated\nSOLUTION:\nA) Water supply stop(s) may be partially closed. Open stop(s).\nB) Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s) if required.\nC) Aerator is clogged. Remove, clean, and reinstall aerator. Replace aerator if required.\nD) Faucet is not working properly. Please contact Equiparts at 800-442-6622 or view replacement EAF-275 complete faucets: #58112, #58114.\n5\nPROBLEM:\nFaucet doesn't stop delivering water or continues to drip after user is no longer being detected\nSOLUTION:\nA) Solenoid Valve is not working properly (#58426).\n6\nPROBLEM:\nLED indicator blinks when faucet is in use\nSOLUTION:\nA) Battery Low. Replace battery (#80775).\n7\nPROBLEM:\nThe water temperature is too hot \/ cold on a faucet connected to hot \/ cold supply lines\nSOLUTION:\nA) Supply stops are not adjusted properly. Adjust supply stops.\nB) For models with integral mixing valve – mixing valve is set improperly for the water temperature desired. Rotate mixing valve handle clockwise to decrease water temperature or counterclockwise to increase water temperature.\nEAF-275 Troubleshooting Guide PDF\nView the Sloan EAF-275 repair parts or our selection of Sloan electronic faucets or view complete EAF-275 faucets: #58112, #58114","brand":"Sloan","offers":[{"title":"Default Title","offer_id":30287716352074,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0259\/3344\/7242\/products\/EAF275_0c057fee-b316-47fe-8760-a1e6c870e36c.jpg?v=1569592523","url":"https:\/\/citysupplycompany.myshopify.com\/products\/sloan-eaf-275-parts-breakdown-and-troubleshooting-guide","provider":"CitySupplyCompany","version":"1.0","type":"link"}